Camcorp CAM-AIRO Vertical Cartridge Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ausrüstung Camcorp CAM-AIRO Vertical Cartridge herunter. CAMCORP CAM-AIRO Vertical Cartridge User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - & Maintenance Manual

Installation, Operation,& Maintenance ManualUnique Design & Engineering Approaches for Industrial ApplicationsCAMCORPCamAiroVertical Cartridge

Seite 2 - 

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com (!,+0!3+24 Step 4: Platform and ladder, if applicable, c

Seite 3 - $%&

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com (!,+0!3+24 Compressed Air Manifold: Typically, CAMCORP s

Seite 4

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com (!,+0!3+24 The firing sequence of the diaphragm valves o

Seite 5 - Section 2 - Receiving

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Auxiliary Equipment: All auxiliary equipment must be installed accord

Seite 6 - 01(- - 21.

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com  • Open the access door on the dust collector. • Depen

Seite 7

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com  • The filter cartridges have a metal mount

Seite 8

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com • After the filter cartridge(s) are all sl

Seite 11

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 4 - Operation ,01(0,5 A. Solids laden air or ga

Seite 12

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Safety Recommendations ...

Seite 13

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 10!,)65. Installation Make sure the unit is secured to the

Seite 14 - 

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 10!,)65.3+24 Explosion Relief Panels – Shear Bolt Style (whe

Seite 15

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 10!,)65.3+24 With the compressed air system operating,

Seite 16

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 10!,%+.057.- . Fan or Blower System Start the fan or blower a

Seite 17

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com )+28 02+0. Dust control systems Reverse start-up procedure, s

Seite 18

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 5 - Component Information The following pages show details of the mec

Seite 19 - Section 4 - Operation

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Explosion Vents (if applicable) - Confirm Vent(s) with Camcorp Camcorp P/N 4000

Seite 20 - 10!,)65.

Specifications – Installation and Operating InstructionsBULLETIN E-97Series DCT1000 Dust Collector Timer ControllerThank you for purchasing the DCT100

Seite 21

Table of Contents . . . . . . . . . . . . . . . .Page No.1.0 Installing the DCT1000 . . . . . . . . . . . . . . .21.1 Power Requirements . . . . . .

Seite 22

4-20 mA ConnectionsReceiverUsing DCT100024V SupplyLowLimitHighLimitPressureLimitSwitches+-Receiver+-Optional ConnectionUsing ExternalPower Supply+Supp

Seite 23

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com  !"Dust Collector...

Seite 24 - )+28 02+0.

when routing the air hoses to ensure that any potential con-densation or moisture will not drain into the sensor. Whereheavy condensation is present,

Seite 25

available. You will note that both the master controllers andslave boards have a telephone style connector mounted onthe upper right hand side of the

Seite 26

63.6 High Alarm SetupThe operation of the High Alarm Setup is identical to the Highand Low Limit Setup and is only available when a pressuremodule is

Seite 27 - BULLETIN E-97

74.4 Error CodesError codes will be displayed on the three-digit display whencertain faults occur. Most of these indicators are associatedwith the d

Seite 28 - 1.0 Installing the DCT1000

Still need help? Please feel free to contact one of our customer service representatives at219-879-8000 or visit us on the web at www.dwyer-inst.com o

Seite 32 - Diagnostics

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 6- Troubleshooting 0+95.)()%+.550 Excessive Pres

Seite 33 - 5.0 Glossary of Terms

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 0+95.)()%+.5503+24Filter Cartridges Loaded with D

Seite 34 - DWYER INSTRUMENTS, INC

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 1 – Safety Recommendations Because this unit may be under pressure or

Seite 35

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 0+95.)()%+.5503+24 Condensation If moisture has be

Seite 36

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 0+95.)()%+.5503+24 Continuous Flow of Dust in the

Seite 37

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 0+95.)()%+.5503+24 Chemical attack Filter material

Seite 38 - Section 6- Troubleshooting

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 0+95.)()- ,0..207.-  Pulsing failure of all valves or t

Seite 39

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 7 – Routine Maintenance Inspection Frequency will vary as widely

Seite 40 - Extremely Low Pressure Drop

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 8 – Appendix Dust Collection Terms & Definitions Air-to-Cloth R

Seite 41

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Pressure Drop – Another term for differential pressure or the drop in pressure

Seite 42 - 0+95.)()- 0

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 2 - Receiving '()*+,-  Prior to accepting the

Seite 43

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 01(- - 21. Baghouse, Bin Vent, Filter Receiver, Dirty Air Hoppe

Seite 44 - Repairs

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 01(- - 21.3+24 Accessory Parts • This includes al

Seite 45 - Section 8 – Appendix

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com 01(- - 21.3+24 Isolation Dampers • All limit switch

Seite 46

CAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271 www.camcorpinc.com Section 3 - Installation (!,+0! CAMCORP dust collectors are shi